A. Control Panel
NOTE: Total power drawn from all receptacles must not exceed
the nameplate ratings.
B. 120 V, 20 Ampere Receptacle
20 amps of current may be drawn from the receptacle.
However, total power drawn must be kept within nameplate
ratings.
C. 120 Volt, 30 Ampere Twistlock Receptacle
You may draw a maximum of 30 amps from this
receptacle. If other receptacles are used at the same time,
total power used must be kept within nameplate ratings.
D. 120/240 V, 30 Ampere Twistlock Receptacle
Maximum full load current may be drawn from the
120/240 volt receptacle. Total current must be limited to
the nameplate rating. If the 120/240 volt receptacle is used
along with the 120 volt receptacle, the total load drawn
must not exceed the nameplate ratings.
E. Circuit Protectors
The receptacles are protected by an AC circuit protector. If the
generator is overloaded or an external short circuit occurs, the circuit
protector will trip. If this occurs,
disconnect all electrical loads and try to determine the cause
of the problem before attempting to use the generator again. If
overloading causes the circuit protector to trip, reduce the
load. NOTE: Continuous tripping of the circuit protector may
cause damage to generator or equipment. The circuit protector
may be reset by pushing the button of the protector.
F. Ground Terminal
G. Air Filter
H. Engine On/Off/Start Switch
I. 445 CC OHV Engine
J. Recoil Starter
K. Engine Choke Lever
L. Oil Filler Cap
M. Oil Drain Plug
N. 7 Gallon Metal Fuel Tank
O. Fuel Tank Cap
P. Fuel Gauge
Q. Fuel Shut-Off Valve
R. Multimeter
When the generator is started, the voltage value is shown first.
Press and release the mode button to toggle between Voltage,
Frequency, Total Hour Meter and Run/Maintenance
Timer.
Voltage (V) displays the operating voltage of the generator.
Frequency (F) displays the frequency in hertz at which the
generator is running.
The Run/Maintenance Timer displays the time in hours and
minutes each time the generator is ran. The run timer resets
to 00:00 when the generator is shut off. Built into this run
timer is a maintenance reminder. When the new generator is
ran for 25 hours, the meter will display P25. This is to
remind you to change the oil after the initial 25 hours of run
time.
When the Run/Maintenance Timer displays P50, it is
reminding you to clean the air filter.
When the Run/Maintenance Timer displays P100, it is
reminding you to change/clean the fuel filter, clean the air
filter, and change the oil.
A
B
Q
E
J
L
M
H
K
O
C
D
F
E
R
N
I
P
English
G
GENERATOR FEATURES
GENERATOR FEATURES
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 51 52